Voyager User’s Manual - EDIT Mode
Page 59
Voyager User’s Manual - EDIT Mode
5.2 T.S. MEM MOD BUS (Touch Surface Memory Modulation Bus)
The TS MEM MOD BUS function is for allowing the last known X and
Y parameters of the Touch Surface inputs to be held in memory after
contact is no longer made with the touch surface. The held values only
apply to those used as the programmable Sources in the Mod Busses,
however. When this function is off, the X and Y values return to zero after
contact with the touch surface is no longer made.
5.3 T. S. MEMORY GLOBAL (Touch Surface Memory Global)
The TS MEMORY GLOBAL function adds memory to the direct
destinations of Touch Surface X and Y inputs. When the Touch
Surface Gate input goes off after being on, the last X and Y values are
remembered until the next time the Gate goes on.
5.4 POT MAPPING S/D (Pot Mapping Source and Destinations)
The POT MAPPING S/D function allows up to four separate modulation
routings, independent of the Mod Busses. In Pot Mapping, the
programmable modulation sources and destinations can be performance
controls (like Pitch Bend or Velocity), or front panel controls (like the LFO
Rate control). Each of the four mappings has it own dedicated menu. Use
the -1/+1 buttons to select the desired map and then press ENTER.
A new menu will appear, similar to the one shown at left for Pot Map 3.
All four map menus are identical and have the same assignable options.
The menu allows you to select the source (SRC), the destination (DEST.),
the direction, and the amount for each of the four mappings. Use the
CURSOR to move to the desired parameter, then use the -1/+1 buttons
to select the desired value.
TS GATE (con’t)
The LFO Restart function is the fourth option in the TS Gate Con-
trol menu. Since the TS Gate Control menu can only display three
options at a time, use the CURSOR to scroll down to the bottom
of the list, where the LFO Restart option will appear.
Use the -1/+1 buttons to switch the LFO Restart function ON or
OFF. When LFO Restart is ON, a Gate ON signal applied to the TS
GATE input on the VX-352 will restart the LFO, generating a new
sample based on the voltages at the TS X,Y, and A inputs of the
VX-352. (Note: For the Gate LFO Restart function to operate, the
front panel LFO SYNC control must be set to “MIDI” when the LFO
Restart function is switched ‘ON’.)